An Improved Olympic Hole-Filling Method for Ultrasound Volume Reconstruction of Human Spine

An Improved Olympic Hole-Filling Method for Ultrasound Volume Reconstruction of Human Spine
View Sample PDF
Author(s): D. E. O. Dewi (University of Groningen, The Netherlands), T. L. R. Mengko (Institut Teknologi Bandung, Indonesia), I. K. E. Purnama (Institut Teknologi, Indonesia), A. G. Veldhuizen (University of Groningen, The Netherlands)and M. H. F. Wilkinson (University of Groningen, The Netherlands)
Copyright: 2012
Pages: 13
Source title: Emerging Communication Technologies for E-Health and Medicine
Source Author(s)/Editor(s): Joel J.P.C. Rodrigues (Senac Faculty of Ceará, Fortaleza-CE, Brazil; Instituto de Telecomunicações, Portugal)
DOI: 10.4018/978-1-4666-0909-9.ch021

Purchase

View An Improved Olympic Hole-Filling Method for Ultrasound Volume Reconstruction of Human Spine on the publisher's website for pricing and purchasing information.

Abstract

Hole-filling in ultrasound volume reconstruction using freehand three-dimensional ultrasound estimates the values for empty voxels from the unallocated voxels in the Bin-filling process due to inadequate sampling in the acquisition process. Olympic operator, as a neighbourhood averaging filter, can be used to estimate the empty voxel. However, this method needs improvement to generate a closer estimation of the empty voxels. In this paper, the authors propose an improved Olympic operator for the Hole-filling algorithm, and apply it to generate the volume in a 3D ultrasound reconstruction of the spine. The conventional Olympic operator defines the empty voxels by sorting the neighbouring voxels, removing the n% of the upper and lower values, and averaging them to attain the value to fill the empty voxels. The empty voxel estimation can be improved by thresholding the range width of its neighbouring voxels and adjusting it to the average values. The method is tested on a hole-manipulated volume derived from a cropped 3D ultrasound volume of a part of the spine. The MAE calculation on the proposed technique shows improved result compared to all tested existing methods.