IRMA-International.org: Creator of Knowledge
Information Resources Management Association
Advancing the Concepts & Practices of Information Resources Management in Modern Organizations

Impact of Number of Slots and Permittivity on EMI Shielding Effectiveness

Impact of Number of Slots and Permittivity on EMI Shielding Effectiveness
View Sample PDF
Author(s): Rangarajan J. (Muthayammal Engineering College, India), Kirubakaran J. (Department of ECE, Muthayammal Engineering College, Rasipuram, India), Praveena R. (Department of ECE, Muthayammal Engineering College, Rasipuram, India)and Shenbagadevi K. (Muthayammal Engineering College, Rasipuram, India)
Copyright: 2022
Pages: 11
Source title: Antenna Design for Narrowband IoT: Design, Analysis, and Applications
Source Author(s)/Editor(s): Balachandra Pattanaik (Wollega University, Ethiopia), M. Saravanan (Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology, India), U. Saravanakumar (Muthayammal Engineering College, India)and Ganesh Babu T R (Muthayammal Engineering College, India)
DOI: 10.4018/978-1-7998-9315-8.ch013

Purchase

View Impact of Number of Slots and Permittivity on EMI Shielding Effectiveness on the publisher's website for pricing and purchasing information.

Abstract

All electronics equipment and devices emit electromagnetic energy. The emitted energy creates electromagnetic interference to the nearby electronic equipment. Shielding is the only effective method of reducing this type of interference without disturbing and reducing the performance of complex electronic systems. Shielding cages usually have openings or slots to provide ventilation and enable access to electronic components placed inside the cage. In this chapter, the impact of dimension of the shielding cage and the number of slots in the shielding cage are investigated. Relative permittivity reflects the electrical characteristics. Its impact on shielding effectiveness is also analyzed in this chapter. Simulation results shows decrease in the shielding effectiveness with the increase in number of slots as well as increase in relative permittivity. In addition, the shielding effectiveness decreases with the increase in frequency.

Related Content

B. Neeraja, Darshan Pradeep Pandit, Nagamani Molakatala, Kalpana Chittor S., Ankita Tiwari. © 2024. 26 pages.
Priyanka Gupta, Shikha Shikha, Monica Bhutani, Jyoti Gupta, Monica Gupta. © 2024. 31 pages.
B. Neeraja, Warshi Singh, K. Arulini, V. Krishnamoorthy, Somu Chinnusamy. © 2024. 26 pages.
Kamalendu Pal. © 2024. 15 pages.
Mallireddy Naresh, D. Abdus Subhahan, Vivek Narula Narula, Dayana K. Roslin, Shaweta Narula, Sampath Boopathi. © 2024. 29 pages.
Suriya Ponnambalam, Ilampoornan M. K.. © 2024. 29 pages.
Adireddy Ramesh, N. Hemalatha, Satyendra Vishwakarma, G. S. V. Seshu Kumar, Vellayan Srinivasan, M. Sudhakar. © 2024. 22 pages.
Body Bottom